I. Five Industry Applications Overview
| Industry |
Typical Process |
Gas / Media |
Fit |
Why This Pump |
| Photovoltaic / mono-Si |
Crystal pulling vacuum, exhaust |
Silicon dust, Ar |
★★★★★ |
Oil-free, 420 m³/h matches medium furnace stations |
| Chemical / petrochemical |
Solvent recovery, exhaust extraction |
Solvent vapor, VOCs |
★★★★★ |
Oil-free chamber, solvent-tolerant, condensable-gas friendly |
| Pharmaceutical |
Freeze drying, distillation, concentration |
Water vapor, alcohols |
★★★★☆ |
Clean oil-free, fits GMP peripheral vacuum stations |
| Food / packaging |
Vacuum packing, pre-cooling, impregnation |
Water vapor, air |
★★★★☆ |
No oil contamination risk, economical for intermittent duty |
| Semiconductor back-end / labs |
Rough vacuum steps, R&D |
N₂, air, clean exhaust |
★★★★☆ |
Excellent value for backup and R&D platforms |
II. Photovoltaic & Monocrystal Silicon
2.1 Typical Duty
- Crystal pulling furnace vacuum and inert-gas systems: stable medium-speed continuous pumping
- Process characteristics: silicon particulates, 24/7 continuous operation
- NC0400 B LZ1 fit:
- 420 m³/h covers a single medium-frequency furnace station
- Dry screw structure tolerates particulates better than oil-sealed pumps
- 0.05 hPa ultimate vacuum meets pulling requirements
2.2 Selection Advice
- PV buyers of used dry pumps value: low unit cost + immediate availability
- At ¥68,500/unit with 3 units in stock, ideal for furnace expansion or batch replacement of aging pumps
- Suggested configuration: 2 running + 1 hot standby for redundancy
III. Chemical & Petrochemical
3.1 Typical Duty
- Solvent recovery and vacuum distillation: heavy condensable solvent vapor load
- Exhaust extraction and VOC transfer: potentially corrosive, fouling media
- NC0400 B LZ1 fit:
- Oil-free chamber — solvent vapor cannot emulsify pump oil
- Dry screw compression handles condensable gas loads
- Only 1.0 L of VE 101 in the gearbox — low running cost
3.2 Selection Advice
- For strongly corrosive media, confirm rotor coating configuration; Taixing can support refurbishment
- Front-end cold trap / dust removal recommended to extend overhaul intervals
IV. Pharmaceutical
4.1 Typical Duty
- Freeze dryer backing pumps, vacuum concentration, distillation recovery
- Media: water vapor, ethanol — cleanliness required
- NC0400 B LZ1 fit:
- Oil-free, prevents oil mist backstreaming into product
- 500 kg unit — flexible vacuum-station layout
4.2 Selection Advice
- GMP peripheral vacuum stations favor dry screw solutions
- Can serve as intermediate/backing stage with water-ring pumps to deepen system vacuum
V. Food & Packaging
5.1 Typical Duty
- Large vacuum packing lines, produce vacuum pre-cooling, impregnation
- Media: mostly water vapor, mostly intermittent
- NC0400 B LZ1 fit:
- Oil-free pumping — zero food-contact oil contamination risk
- Used pricing cuts packaging-line vacuum capex dramatically
5.2 Selection Advice
- Intermittent duty consumes equipment slowly — used pumps shine economically
- Manage gas ballast / condensate drainage properly
VI. Semiconductor Back-End & Laboratory
6.1 Typical Duty
- Rough vacuum steps outside cleanrooms, chamber pre-pumping, R&D platforms
- NC0400 B LZ1 fit:
- Backing pump for roots booster sets or standalone rough vacuum
- Lab duty of 4-8 h/day leaves ample equipment margin
6.2 Selection Advice
- For budget-limited R&D platforms, a used Busch delivers "top-brand performance at half the price"
- Backup requirement: 3 units in stock can cover main + standby in one purchase
VII. Universal Advantages of Used Pumps Across Industries
| Dimension |
Detail |
| Cost |
¥68,500/unit — roughly 40-50% of new price |
| Lead time |
3 units in stock, ships immediately — no European lead time |
| Condition |
90% new, well maintained, ready to install; installation included in Fujian |
| Brand |
Busch first-tier brand with mature parts and service ecosystem |
| Flexibility |
Ideal for backup, expansion, pilot lines, R&D platforms |
VIII. FAQ
Q1: Can this pump handle corrosive gases?
A: The COBRA NC series tolerates most chemical media well. For strongly corrosive duty, tell us the gas composition so we can confirm the coating configuration.
Q2: Can it pump water vapor?
A: Yes. Dry screw pumps handle condensable vapor well; manage gas ballast and drainage per your duty.
Q3: Is 420 m³/h enough for a crystal pulling furnace?
A: Yes — it matches a single medium-frequency furnace station; multiple furnaces can run pumps in parallel (3 in stock).
Q4: Any concern about used pumps for pharma?
A: The oil-free chamber is inherently clean, units are cleaned and tested before delivery, and GMP-peripheral vacuum stations use them widely.
Q5: Is a used pump worthwhile for a lab running a few hours daily?
A: Extremely worthwhile. Intermittent duty wears equipment slowly — ¥68,500 gets a top-brand 420 m³/h dry pump.
Q6: Can 3 pumps form a vacuum station?
A: Yes. 3 units in parallel form a ~1260 m³/h class dry vacuum station; Taixing provides piping design advice.
Q7: How do remote customers complete installation?
A: Units ship nationwide; installation is included in Fujian and engineers can be arranged elsewhere.