Pfeiffer series built-in leaks are specially designed for helium detectors like Pfeiffer 340/390/310, featuring microchannel capillary technology to provide accurate and stable leakage rate detection. Learn about technical parameters, product features and FAQs to choose reliable calibration solutions.
This article details the technical parameters, product features, application scenarios and FAQs of Pfeiffer series built-in leaks, with special focus on its microchannel capillary technology and thickened aluminum construction, providing precise and stable calibration solutions for helium detectors.
Microchannel capillary technology: Ensures precise and stable leakage volume with long-term rate stability
Multi-interface compatibility: Standard and customized interfaces for various helium detectors
Customization service: Supports specified leakage rates and multiple gas types
Durable design: Thickened all-aluminum construction for extended service life
Authoritative certification: Provides internal/third-party CNAS calibration certificates
Parameter |
Specifications |
Model |
TK-07 |
Type |
Built-in leak |
Applicable gas |
He4 |
Leak rate range (He4) |
1.0-8.0E-7mbar.L/s |
Charging pressure |
0.1-2MPa |
Leak rate tolerance |
±10% |
Gas chamber volume |
50mL |
Outlet connector |
Pfeiffer 340/ASM142 |
Leak process |
Channel capillary technology |
Valve configuration |
No valve |
Temperature drift |
0.1%/°C |
Annual loss rate |
3%/year |
Certification |
Internal/CNAS calibration cert |
Dimensions |
122mm*∅35mm |
Internal calibration for Pfeiffer 340/ASM 142 helium detectors
Periodic verification of helium mass spectrometers
Vacuum system leak tightness testing
High-precision leakage rate calibration
Equipment: Pfeiffer ASM 340 helium mass spectrometer
Scenario: Semiconductor packaging production line
Solution: Using TK-07 built-in leak for regular equipment calibration, maintaining detection accuracy of 1.0E-7mbar.L/s to effectively control packaging airtightness quality.
Ensure clean, contamination-free interfaces before installation
Use dedicated tools for sealed connections
Perform regular leak rate verification (recommended quarterly)
Store in dry and clean environment
1、How to determine if built-in leak needs replacement?
Consider replacement when calibration deviation exceeds ±15% or response time significantly prolongs.
2、How to compensate temperature drift?
Recommend standard operation at 23±2℃. Recalibration needed for every 10℃ temperature change.
3、Does it support non-helium detection?
Customization available for Ar, N2 etc., but gas type must be specified in advance.
4、How to adapt interfaces for different helium detectors?
Provides standard interface customization for Pfeiffer/Varian/Agilent etc.
5、How to control annual loss rate?
Recommend annual CNAS certification calibration to establish loss curve.
6、Advantages of microchannel capillary technology?
Better contamination resistance and stability compared to traditional sintered leaks.
7、What if charging pressure exceeds range?
May cause nonlinear leak rate change or even capillary structure damage.
8、Can leaks be repaired on-site?
Capillary components cannot be repaired, recommend direct standard module replacement.
9、How to verify leak accuracy?
Requires cross-verification using standard leak comparison device.
10、Lead time for customized leak rates?
3 workdays for standard models, 7-15 workdays for special leak rates.