This article details the technical specifications, application cases, and FAQs of KYKY FF160/620N grease-lubricated turbo molecular vacuum pump bearings, helping users understand the performance and maintenance of these core components.
The KYKY FF160/620N grease-lubricated bearings are critical components of turbo molecular pumps, directly impacting performance and lifespan. This article provides technical parameters, case studies, and troubleshooting tips to optimize vacuum system operation.
KYKY FF160/620N bearings, turbo molecular pump bearings, vacuum pump core components, grease-lubricated bearings, molecular pump upper/lower bearings, turbo pump maintenance, vacuum pump specifications
Turbo molecular vacuum pumps are essential for high-end vacuum systems, and the KYKY FF160/620N grease-lubricated bearings play a crucial role in their efficiency and stability. This article covers technical specifications, real-world applications, and FAQs to guide selection and maintenance.
Parameter |
Specification |
Compatible Model |
KYKY FF160/620N Turbo Pump |
Bearing Type |
High-Speed Grease-Lubricated |
Speed Range |
20,000 - 60,000 RPM |
Ultimate Vacuum |
≤ 5×10⁻⁶ Pa (with turbo pump) |
Lubrication |
High-performance vacuum grease |
Service Life |
≥ 20,000 hours (normal use) |
Operating Temperature |
-20°C to 120°C |
Material |
Precision hybrid ceramic/stainless steel bearings |
Installation |
Precision press-fit, requires alignment |
Case: Vacuum System Upgrade for a Semiconductor Manufacturer
Issue: Worn-out turbo pump bearings caused vacuum instability, affecting thin-film deposition.
Solution: Replaced with KYKY FF160/620N grease-lubricated bearings and optimized lubrication.
Result: Restored vacuum to ≤ 5×10⁻⁶ Pa, reduced noise by 30%, and extended maintenance intervals to 2+ years.
Q1: Do KYKY FF160/620N bearings require regular relubrication?
A: No, they use long-life vacuum grease, but inspect every 2 years.
Q2: What causes bearing failure?
A: Contamination, insufficient lubrication, overspeeding, or improper installation.
Q3: How to tell if bearings need replacement?
A: Unusual noise, increased vibration, or degraded vacuum performance.
Q4: Can standard bearings be used as replacements?
A: No—specialized bearings are required for high-speed vacuum environments.
Q5: Installation precautions?
A: Use precision tools, ensure alignment, and avoid shock loads.
Q6: What’s the maximum operating temperature?
A: Recommended range: -20°C to 120°C. Excess heat degrades grease.
Q7: How to store spare bearings?
A: Keep in a dry, dust-free environment, sealed to prevent grease oxidation.
Q8: How to maximize bearing lifespan?
A: Maintain clean vacuum conditions, avoid frequent start-stop cycles, and monitor vibrations.
Q9: Are custom bearings available?
A: Yes, customized materials or lubrication options can be provided.
Q10: Is recalibration needed after bearing replacement?
A: Yes, dynamic balancing is required for optimal performance.
The KYKY FF160/620N grease-lubricated bearings are vital for turbo molecular pump reliability. Proper selection, installation, and maintenance can significantly enhance vacuum system performance. For technical support, contact our expert team.
(End of News)
This article integrates SEO elements (title, meta description, keywords, structured content) and is suitable for corporate websites, industry portals, or technical forums to improve search engine visibility.
Tags :