CF Variable Diameter Fixation Series - Precision Vacuum Connection Solutions
This series of reducers offers multiple size combinations, with various specifications available from CF35 to CF150, meeting the connection requirements of various vacuum systems. Each product undergoes helium mass spectrometry leak testing to ensure leak rates below 1×10⁻¹⁰ Pa·m³/s, making it an ideal choice for scientific research and industrial applications.
Precision Machining - All dimensions strictly controlled within ±0.1mm tolerance range
Premium Materials - Uses 304 or 316 stainless steel ensuring corrosion resistance
Reliable Sealing - Helium mass spectrometry leak tested for ultra-high vacuum performance
Multiple Specifications - Various size combinations from CF35 to CF150 available
Wide Applications - Suitable for scientific instruments, semiconductor equipment, and various other fields
Precise Dimension Control
All machining dimensions strictly comply with international standards
Surface finish reaches Ra≤0.8μm
Strict flatness and parallelism control
High-Quality Material Selection
304/316 stainless steel material
Excellent corrosion resistance
Good stability in high-temperature environments
Reliable Sealing Performance
Helium leak rate <1×10⁻¹⁰ Pa·m³/s
Special surface treatment process
Aging tested for long-term stability
Easy Installation
Standardized flange interfaces
Clear dimension markings
Comprehensive installation guidance
Quality Assurance
100% quality inspected
Material certification reports provided
Complete traceable inspection records
Model |
A (mm) |
B (mm) |
C (mm) |
D (mm) |
CF35RA16 |
70 |
34 |
76 |
19.05 |
CF35RA25 |
70 |
54 |
76 |
25.4 |
CF63RA16 |
114 |
34 |
76 |
19.05 |
CF63RA25 |
114 |
54 |
76 |
25.4 |
CF63RA35 |
114 |
70 |
76 |
38.1 |
CF100RA35 |
152 |
70 |
76 |
38.1 |
CF100RA63 |
152 |
114 |
76 |
63.5 |
CF150RA35 |
202 |
70 |
76 |
38.1 |
CF150RA63 |
202 |
114 |
76 |
63.5 |
CF150RA100 |
202 |
152 |
76 |
101.6 |
General Specifications:
Material: 304/316 stainless steel
Operating Temperature: -20℃ to 200℃
Surface Treatment: Electropolishing
Vacuum Level: Up to 10⁻¹⁰ Pa
Sealing Method: Metal gasket sealing
Scientific Instruments
Electron microscope vacuum systems
Mass spectrometer connection systems
Surface analysis instruments
Semiconductor Equipment
Coating equipment vacuum connections
Etching machine vacuum systems
Ion implantation equipment
Accelerator Devices
Particle accelerator vacuum pipelines
Synchrotron radiation devices
Vacuum beam transmission systems
Industrial Equipment
Vacuum furnace connection systems
Freeze-drying equipment
Vacuum packaging machinery
Pre-installation Preparation:
Clean all sealing surfaces
Check if gaskets are intact
Prepare appropriate installation tools
Installation Steps:
Place metal gasket in the sealing groove
Align flange bolt holes
Tighten bolts evenly using crisscross pattern
Use torque wrench with recommended torque values
Perform leak detection
Recommended Torque:
CF35 Series: 5-6 N·m
CF63 Series: 8-10 N·m
CF100 Series: 12-15 N·m
CF150 Series: 18-20 N·m
Precautions:
Avoid reusing metal gaskets
Ensure sealing surfaces are clean and undamaged
Use specified torque values
Leak detection must be performed after installation
Q: How to choose the appropriate reducer model?
A: Select the corresponding model based on the sizes of the two CF flanges that need to be connected in your system. For example, CF35RA16 indicates one end is CF35 flange, the other end is CF16 flange.
Q: Can metal gaskets be reused?
A: Reusing metal gaskets is not recommended as each compression causes permanent deformation, affecting sealing effectiveness.
Q: What should be特别注意 during installation?
A: Ensure absolute cleanliness of sealing surfaces, use correct installation torque, and tighten bolts evenly in crisscross pattern.
Q: What is the vacuum performance of these reducers?
A: All reducers undergo helium mass spectrometry leak testing with leak rates below 1×10⁻¹⁰ Pa·m³/s, suitable for ultra-high vacuum applications.
Q: Are custom sizes available?
A: We can provide custom services according to customer requirements, but detailed technical specifications are needed.
Q: How to determine if a reducer needs replacement?
A: If there is irreparable leakage, or visible damage and corrosion on sealing surfaces, replacement is needed.
Q: What is the service life of these reducers?
A: Under normal use and maintenance conditions, they can be used for over 10 years, depending on usage environment and frequency.
Q: Are material certificates provided?
A: Yes, we can provide complete material certificates and test reports.
Q: How to clean and maintain?
A: Recommend using lint-free cloth with acetone or alcohol for wiping, avoid using corrosive cleaners.
Q: What is the delivery time?
A: Standard models are usually in stock with 3-5 days delivery. Special specifications require 2-3 weeks production time.
The CF Variable Diameter Fixation Series, with its precise machining工艺, excellent sealing performance, and reliable quality assurance, serves as an ideal connection solution for ultra-high vacuum systems. Whether for scientific research or industrial production, this product series can provide stable and reliable performance. We recommend users select appropriate models based on actual needs and strictly follow installation instructions to ensure optimal performance.
Professional Advice: We recommend users establish regular inspection and maintenance plans, replace metal gaskets after each disassembly, and record installation torque and test results each time to ensure long-term stable operation of the vacuum system.
Tags :