3G.2 CELL Extraction Electrode - Replacement for Pfeiffer ASM 310/340 Leak Detectors P/N:119641 f 21, 2025

The 3G.2 CELL Extraction Electrode (Pfeiffer P/N: 119641, Vendor PN22454) is a high-quality replacement part designed for Pfeiffer Adixen ASM 310 and ASM 340 helium mass spectrometer leak detectors. As a critical component of the 3G analyzer cell, this electrode ensures efficient helium ion extraction, delivering high sensitivity and stable leak detection performance. Constructed from high-purity metal and ceramic composite, it matches original specifications for seamless compatibility and durability.

Featuring a plug-and-play design, the electrode enables quick, tool-free replacement, minimizing downtime during maintenance. It is recommended to inspect or replace every 6–12 months, depending on usage and environmental conditions. Ideal for semiconductor manufacturing, aerospace, and vacuum system maintenance, this cost-effective part offers performance equivalent to OEM components without requiring modifications. Compatible with ASM 310 and ASM 340 models, it is essential for precise helium leak detection.

This original-quality extraction electrode (P/N 119641) ensures high sensitivity and stable performance in Pfeiffer Adixen helium mass spectrometer leak detectors. Designed for ASM 310 and ASM 340 models, it features plug-and-play installation and durable composite materials.

 


Designed to maintain optimal detection performance, this 3G.2 CELL extraction electrode replacement is fully compatible with Pfeiffer Adixen ASM 310 and ASM 340 leak detectors. Made with high-purity metal and ceramic materials, it ensures accurate helium ion extraction and long-term reliability.

High-Precision Extraction Electrode Replacement for Pfeiffer Adixen ASM 310 / ASM 340
Why Choose the 3G.2 CELL Extraction Electrode Replacement?
The 3G.2 CELL Extraction Electrode is a critical component in helium mass spectrometer leak detectors, ensuring efficient extraction of helium ions for precise leak detection. This high-quality replacement matches original Pfeiffer specifications, providing reliable performance and consistent sensitivity over time. It features durable construction and a plug-and-play design for hassle-free replacement and maintenance.

Whether in aerospace, semiconductors, or industrial manufacturing, this electrode supports stable operation and minimizes downtime by maintaining accurate leak detection performance.

Key Features of the 3G.2 CELL Extraction Electrode Replacement
High Sensitivity Performance
Maintains optimal helium ion extraction for accurate leak detection results.

Full Compatibility
Engineered for seamless integration with Pfeiffer Adixen ASM 310 and ASM 340 models.

Premium Materials
Constructed with high-purity metal and ceramic composites for enhanced durability.

Plug-and-Play Installation
No calibration tools or modifications required—just insert and go.

Stable Operation
Ensures instrument consistency even under heavy usage or long operating cycles.

Cost-Effective Alternative
Offers the same quality as OEM parts at a more economical price point.

Applications of the 3G.2 CELL Extraction Electrode Replacement
Helium Leak Detection in Manufacturing
Enables accurate testing for product seal integrity in industrial and high-tech environments.

Semiconductor Equipment Maintenance
Supports vacuum integrity checks for sensitive semiconductor processes.

Aerospace Component Testing
Ensures high-precision leak detection in mission-critical aerospace systems.

Technical Specifications

Specification

Value

Product Type

Extraction Electrode Assembly

Compatible Models

Pfeiffer Adixen ASM310/ASM 340

Replacement Part Number

119641

Replacement Type

3G(Third-Generation)Replacement  Component

Compatibility

Replaces OEM filament assembly

(excluding full detectorunit)

FAQ: 3G.2 CELL Extraction Electrode Replacement
What does this electrode do?
It extracts helium ions from the mass spectrometer chamber, enabling precise leak detection.

Which leak detector models is it compatible with?
It is specifically designed for Pfeiffer Adixen ASM 310 and ASM 340 series.

Is it an original OEM part?
No, it's a high-performance aftermarket replacement, offering equivalent or superior quality.

Does it require special tools for installation?
No tools are needed. The electrode features a plug-and-play design for easy replacement.

How often should I replace the electrode?
We recommend inspecting or replacing it every 6–12 months, depending on usage and environment.

Will it affect the leak detector’s sensitivity?
Not at all. It is designed to maintain the high sensitivity and performance of the original part.

Is calibration required after installation?
Yes, a system calibration is recommended to verify optimal detection accuracy.

What material is it made of?
It is constructed from high-purity metal and ceramic composite for excellent stability and durability.

Can this electrode withstand harsh environments?
Yes, it is engineered for use in demanding industrial settings with stable thermal and chemical resistance.

Is it cost-effective compared to OEM parts?
Absolutely. It offers OEM-level performance at a more competitive price point, reducing maintenance costs.

 

Conclusion: Consistent Performance for Helium Leak Detection
The 3G.2 CELL extraction electrode replacement offers a reliable and cost-effective solution for maintaining the performance of your Pfeiffer Adixen ASM 310 or ASM 340 leak detectors. Built with high-grade materials and designed for easy replacement, it ensures consistent sensitivity and long-term stability across demanding industrial applications.

categories
Newsletter
Join our mailing list, you will get new product release and event information as soon as possible latter

leave a message

leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit

home

products

WhatsApp