Main features
· Extensive pressure options: Choose between the 10 Torr (RBM35011T1) and the 100 Torr (RBM35012T1) models.
· Accurate measurement: Advanced membrane capacitance technology ensures accuracy and stability.
· Standardized connection: ISO-KF DN 16 flange, compatible with various systems.
· Durable construction: specifically designed for the demanding industrial and laboratory environments.
· Multiple applications: suitable for research, manufacturing, and quality control.
Application
1. Laboratory research:
· Provide precise vacuum readings for experiments requiring a controlled environment.
2. Semiconductor manufacturing:
· Ensure accurate vacuum control during key wafer processing and chip production.
3. Industrial process:
· Reliable vacuum monitoring for drying, coating, and degassing operations.
4. Quality control:
· It is helpful for accurate vacuum testing and validation on the production line.
6. Model-specific details
model
|
pressure limit
|
contact
|
part number
|
RBM35011T1
|
10 To
|
ISO-KF DN 16
|
RBM35011T1
|
RBM35012T1
|
100 To
|
ISO-KF DN 16
|
RBM35012T1
|
7. Advantages
· Reliable measurement: Capacitance technology minimizes drift and achieves accurate and stable readings.
· Easy integration: ISO-KF DN 16 flanges ensure quick and seamless installation.
· Durability: Designed to withstand rigorous industrial and laboratory use.
· Applied versatility: Perfect for semiconductors, research, and industrial processes.
8. Picture SEO precautions
RBM350 Film capacitance vacuum meter 10 Torr and 100 Torr (ISO-KF DN 16)
The image shall display two models, labeled RBM35011T1 (10 Torr) and RBM35012T1 (100 Torr), highlighting their ISO-KF DN 16 connection and durable construction. Include annotation to emphasize precision, reliability, and applied versatility.
9. Call for action
Encourage users:
· Request the quote for the RBM350 vacuum meter (10 Torr or 100 Torr).
· Contact you for technical specifications and application support.
· Explore compatible models and accessories for the integrated vacuum system.
This SEO strategy positions RBM35011T1 and RBM35012T1 as reliable, accurate vacuum measurement solutions for a variety of applications, highlighting their durability, accuracy, and compatibility. If you need further improvement, please let me know!
You say:
Membrane capacitor vacuum meter RBM350,100 T орр, ISO-KF DN 16 RBM35012T1 diaphragm capacitance vacuum meter RBM350,1000 T орр, ISO-KF DN 16 RBM35013T1
ChatGPT Says:
Answers to Common Questions about the RBM350 Thin - Film Vacuum Transmitter
1. How is the RBM350 thin - film vacuum transmitter calibrated?
The RBM350 thin - film vacuum transmitter adopts advanced calibration technology and can be calibrated through professional calibration equipment. During the calibration process, connect a standard pressure source to the transmitter, and adjust the parameters of the transmitter to make the output measurement data consistent with the pressure value of the standard pressure source. The calibration process is simple and convenient, and can ensure the measurement accuracy of the transmitter.
2. Will the measurement accuracy of the RBM350 thin - film vacuum transmitter be affected in different temperature environments?
The RBM350 thin - film vacuum transmitter has a good temperature - compensation function, and its measurement accuracy is less affected in different temperature environments. The built - in temperature sensor can monitor the ambient temperature in real - time and automatically compensate the measurement data according to the temperature change, ensuring accurate measurement results under various temperature conditions.
3. What is the response time of the RBM350 thin - film vacuum transmitter?
The response time of the RBM350 thin - film vacuum transmitter is extremely short, usually in the millisecond level. This means that it can quickly capture the changes in vacuum degree and timely transmit the measurement data to the control system, meeting the application scenarios with extremely high real - time requirements.
4. What types of output signals does the RBM350 thin - film vacuum transmitter have?
The output signals of the RBM350 thin - film vacuum transmitter mainly include two types: analog signals and digital signals. The analog signals are usually 4 - 20mA current signals or 0 - 5V voltage signals, and the digital signals can be output through communication interfaces such as RS485 and RS232, which is convenient for docking with various automated control systems.
5. What is the protection level of the RBM350 thin - film vacuum transmitter?
The protection level of the RBM350 thin - film vacuum transmitter is IPXX, which can effectively prevent the erosion of external factors such as dust and water vapor on the equipment. The specific protection level can be customized according to user needs to adapt to different working environments.
6. How does the RBM350 thin - film vacuum transmitter connect with other equipment?
The RBM350 thin - film vacuum transmitter can be connected to equipment such as vacuum pumps and vacuum valves through vacuum pipelines to realize the measurement and control of the vacuum degree. At the same time, it is connected to the control system through electrical lines to transmit the measurement data to the control system and realize automated control. The connection process is simple and only needs to be operated according to the equipment instruction manual.
7. What is the maintenance cycle of the RBM350 thin - film vacuum transmitter?
The maintenance cycle of the RBM350 thin - film vacuum transmitter is relatively long. Generally, maintenance is carried out once every six months or one year. The maintenance content mainly includes cleaning the equipment surface, checking the connection of electrical lines, and calibrating the measurement accuracy. In harsh working environments, the maintenance cycle can be appropriately shortened to ensure the normal operation of the equipment.
8. What should be done if the RBM350 thin - film vacuum transmitter fails during use?
If the RBM350 thin - film vacuum transmitter fails during use, first check whether the power supply, electrical line connection, and vacuum pipeline connection of the equipment are normal. If there are no problems in these aspects, contact the equipment supplier or professional maintenance personnel for maintenance. During the maintenance process, the maintenance personnel will troubleshoot and repair according to the fault phenomenon to ensure that the equipment returns to normal operation.
9. Which gases' vacuum degrees can the RBM350 thin - film vacuum transmitter measure?
The RBM350 thin - film vacuum transmitter can measure the vacuum degrees of various gases, including common gases such as air, nitrogen, oxygen, hydrogen, and helium, as well as some corrosive gases and special gases. When measuring corrosive gases, appropriate materials and protective measures need to be selected according to the properties of the gases to ensure the normal operation and service life of the transmitter.
10. What is the service life of the RBM350 thin - film vacuum transmitter?
The service life of the RBM350 thin - film vacuum transmitter is relatively long. Under normal use and maintenance conditions, it can be used for 5 - 10 years. It adopts high - quality materials and advanced manufacturing processes to ensure the reliability and durability of the equipment. At the same time, regular maintenance and upkeep also help to extend the service life of the equipment.