The TXW 200–500 series pumps are 100% oil less rotary vane vacuum pumps. They are designed to operate on a continuous basis at any point from atmospheric pressure to a maximum vacuum level of
25"HgV, depending on the model. lubricating graphite composite vanes. Applications include those where regenerative blowers These 100% oil-less, or dry, pumps are ideal for The TXW series pumps are direct drive units and are supplied with TEFC flange mounted electric motors. Each pump is equipped with an integral vacuum relief valve, a 4-micron inlet filter, exhaust silencer, and vibration isolators as standard equipment. applications where oil or water use is objectionable. All Becker TXW series pumps use long-life, self cannot reach a deep enough vacuum, or those where oil-flooded vacuum pumps operate at vacuum levels that emit excessive oil aerosols, often referred to as “smoke”. TXW pumps are ideal for graphic arts, pack aging, vacuum chucking, robotics and material handling, medical/surgical, and air sampling, among others. Also available in tank mounted simplex and duplex, and modular/expandable central vacuum system configurations. Pressure and combination pressure/ vacuum pumps are also available
Step1: inhale and seal all the air in the volume chamber, and the compression begins;
Step 2: continue to compress to the center point of the volume cavity;
Step3: compress the air to the center of the volume chamber, and the exhaust will begin soon;
Step4: exhaust, end of a compression process
Step1: inhale and seal all the air in the volume chamber, and the compression begins;
Step 2: continue to compress to the center point of the volume cavity;
Step3: compress the air to the center of the volume chamber, and the exhaust will begin soon;
Step4: exhaust, end of a compression process
Standard leak hole, suitable for helium mass spectrometry vacuum leak detector, channel type open, positive pressure and negative pressure, leakage rate support customization, leakage rate range: 1x10-3Pam3/s ~ 5x10-10Pam3/s,
Straight-through helium standard leakage hole, 1 *10-3Pam3/s ~ 1 *10-7 Pam3/s large leakage rate standard leak hole. Seepage helium type standard leakage hole is not suitable for large leakage rate standard leakage hole because it will be seriously attenuated.Helium mass spectrometry leak detector using out-of-machine calibration if only -8 or -9 leak holes do not represent the large leakage rate of -4 and 5 is also accurate, Therefore, the external calibration needs to be calibrated at the same time as the standard leakage hole of the large leakage rate and the small leakage rate to ensure that the equipment is normal
Provide domestic ion source filament suitable for Agilent VS/HLD helium mass spectrometry leak detector, instead of R3428301applicable Agilent VS series HLD series:PR02PD03MR15MD30BR15BD30
domestic ion source filament 053146/053146Y, suitable for Pufa Alcatel helium mass spectrometry leak detector, new filament bracket, the same quality life, iridium gold filament 053146 life is far more than tungsten filament 053146, more economical and practical (see the photo of the physical object), suitable for Alcatel, Pufa, Zhongke instrument A wide range of helium mass spectrometry leak detectors, including: Alcatel, ADIXEN, Pufa various models of helium mass spectrometry leak detector ASM 142 / 142S / 142DASM 310ASM 380ASM 182 T / TD+ ASM 192 T / T2D+ASM 1002ASI 20ASI 30ASM 102 S
Zhongke instrument various helium mass spectrometry leak detector ZQJ-542GZQJ-542 delivery time commitment: SF within 24 hours of receiving the goods.
Quality commitment: the store's tungsten filament ion source and the original filament have the same quality and life, if there is a quality problem can be replaced within 30 days from the date of shipment with the parameter code and date code on the box, due to improper use or equipment problems caused by serious deformation of the filament and wire breakage is not within the scope of protection.
Applicable to ZQJ-230D.230E.530.2000 leak detector.
There are 3 kinds of materials used in the filament, the first conventional material - the filament special tungsten filament (life is equivalent to the ordinary ion source of the original factory), the second material - the yttrium-plated tungsten wire (twice the life of the original tungsten filament, equivalent to the original yttrium plating ion source), the third material -Yttrium-plated iridium gold wire (independently developed, 10 times that of the original ordinary ion source). The original Zhongke Instrument ion source has no warranty (false one penalty ten).
If the ion source maintenance needs the original ion source filament rack to be sent over, we replace it with the new filament and ship it after passing the test.
Delivery time commitment: SF within 24 hours of receiving the goods.
The TXW 200–500 series pumps are 100% oil less rotary vane vacuum pumps. They are designed to operate on a continuous basis at any point from atmospheric pressure to a maximum vacuum level of
25"HgV, depending on the model. lubricating graphite composite vanes. Applications include those where regenerative blowers These 100% oil-less, or dry, pumps are ideal for The TXW series pumps are direct drive units and are supplied with TEFC flange mounted electric motors. Each pump is equipped with an integral vacuum relief valve, a 4-micron inlet filter, exhaust silencer, and vibration isolators as standard equipment. applications where oil or water use is objectionable. All Becker TXW series pumps use long-life, self cannot reach a deep enough vacuum, or those where oil-flooded vacuum pumps operate at vacuum levels that emit excessive oil aerosols, often referred to as “smoke”. TXW pumps are ideal for graphic arts, pack aging, vacuum chucking, robotics and material handling, medical/surgical, and air sampling, among others. Also available in tank mounted simplex and duplex, and modular/expandable central vacuum system configurations. Pressure and combination pressure/ vacuum pumps are also available
Step1: inhale and seal all the air in the volume chamber, and the compression begins;
Step 2: continue to compress to the center point of the volume cavity;
Step3: compress the air to the center of the volume chamber, and the exhaust will begin soon;
Step4: exhaust, end of a compression process
Step1: inhale and seal all the air in the volume chamber, and the compression begins;
Step 2: continue to compress to the center point of the volume cavity;
Step3: compress the air to the center of the volume chamber, and the exhaust will begin soon;
Step4: exhaust, end of a compression process
Standard leak hole, suitable for helium mass spectrometry vacuum leak detector, channel type open, positive pressure and negative pressure, leakage rate support customization, leakage rate range: 1x10-3Pam3/s ~ 5x10-10Pam3/s,
Straight-through helium standard leakage hole, 1 *10-3Pam3/s ~ 1 *10-7 Pam3/s large leakage rate standard leak hole. Seepage helium type standard leakage hole is not suitable for large leakage rate standard leakage hole because it will be seriously attenuated.Helium mass spectrometry leak detector using out-of-machine calibration if only -8 or -9 leak holes do not represent the large leakage rate of -4 and 5 is also accurate, Therefore, the external calibration needs to be calibrated at the same time as the standard leakage hole of the large leakage rate and the small leakage rate to ensure that the equipment is normal
Provide domestic ion source filament suitable for Agilent VS/HLD helium mass spectrometry leak detector, instead of R3428301applicable Agilent VS series HLD series:PR02PD03MR15MD30BR15BD30
domestic ion source filament 053146/053146Y, suitable for Pufa Alcatel helium mass spectrometry leak detector, new filament bracket, the same quality life, iridium gold filament 053146 life is far more than tungsten filament 053146, more economical and practical (see the photo of the physical object), suitable for Alcatel, Pufa, Zhongke instrument A wide range of helium mass spectrometry leak detectors, including: Alcatel, ADIXEN, Pufa various models of helium mass spectrometry leak detector ASM 142 / 142S / 142DASM 310ASM 380ASM 182 T / TD+ ASM 192 T / T2D+ASM 1002ASI 20ASI 30ASM 102 S
Zhongke instrument various helium mass spectrometry leak detector ZQJ-542GZQJ-542 delivery time commitment: SF within 24 hours of receiving the goods.
Quality commitment: the store's tungsten filament ion source and the original filament have the same quality and life, if there is a quality problem can be replaced within 30 days from the date of shipment with the parameter code and date code on the box, due to improper use or equipment problems caused by serious deformation of the filament and wire breakage is not within the scope of protection.
Applicable to ZQJ-230D.230E.530.2000 leak detector.
There are 3 kinds of materials used in the filament, the first conventional material - the filament special tungsten filament (life is equivalent to the ordinary ion source of the original factory), the second material - the yttrium-plated tungsten wire (twice the life of the original tungsten filament, equivalent to the original yttrium plating ion source), the third material -Yttrium-plated iridium gold wire (independently developed, 10 times that of the original ordinary ion source). The original Zhongke Instrument ion source has no warranty (false one penalty ten).
If the ion source maintenance needs the original ion source filament rack to be sent over, we replace it with the new filament and ship it after passing the test.
Delivery time commitment: SF within 24 hours of receiving the goods.